Index

1. Layout drawing — top-down view

NP OD PP bulk tap 1 2 3 4 5 6 S D₁₂ S D₃₄ S D₅₆ S M1 — GND rail R = 2 Ω R = 2 Ω D₁₂: 0 Ω from tap D₃₄: 2 Ω from tap D₅₆: 2+2 = 4 Ω from tap gout tap / CDM arrival point zap current entering at gout tap sees increasing series M1 R toward fingers 5,6
Fig. 1 — Top-down layout. Three shared-drain pairs (1,2 / 3,4 / 5,6). Drain M1 bus (gout) tapped at left; narrow bus segments add 2 Ω per hop. Sources strapped up to the M1 GND rail; PP/OD bulk tap ring at far left.

1.2 Layer legend

LayerColorUse in Fig. 1
M1GND rail, source straps, gout drain bus + stubs
COContact columns on every S/D stripe and bulk tap
POGate fingers 1–6
ODActive band (S/D diffusions) + bulk-tap active
NPN+ implant enclosing the NMOS active
PPP+ implant for substrate tap ring

2. Resistance ladder & current-share estimate

Assumes RRPO ≈ 8 Ω per finger (from prior sizing). Total per-pair ballast = RRPO,pair (≈ 4 Ω per shared-drain pair, two fingers in parallel) + M1 ladder R. Shares computed per pair by conductance ratio.
Rank🖐️ Pair🛣️ M1 R from tap🧊 + pair RPOΣ R to tap⚡ Est. current share📊
#1Fingers 1, 2 (D₁₂)0 Ω4 Ω4 Ω~46%
#2Fingers 3, 4 (D₃₄)2 Ω4 Ω6 Ω~31%
#3Fingers 5, 6 (D₅₆)4 Ω4 Ω8 Ω~23%

3. Reading notes — what the asymmetry does during a zap

Fingers 1,2 are the new green pair. With the gout tap at the left, the M1 ladder steers ~2× the current of pair 5,6 into pair 1,2 (46% vs 23%). The nearest pair to the tap point runs hottest and filaments first — the layout reproduces exactly the mixed-ballast lean case (0 / 2 / 4 Ω on top of ~4 Ω pair RPO ≈ 4/6/8 Ω totals → ~60/40-style lean spread over three rungs).
Fixes that flatten the ladder: center-tap the gout bus between D₃₄ (drops worst-case to 2 Ω), widen the bus so each hop <0.5 Ω, or fishbone-tap all three drain stubs to a wide trunk. Alternatively exploit it: intentionally shorten RPO on pairs 3–6 by the metal delta so Σ R matches 8 Ω on all rungs.